PART NUMBER PRICES
HTS820TC Telemetry Central Station with: $12995.00
17” Color Monitor Mouse Control, Network
Interface, 120 Mb Super Drive, Fax/Modem,
Backup Hard Drive, Telemetry Enclosure,
Laser Printer, Uninterruptable Power Supply
OPTIONS
CMT TOUCH SCREEN 15” LCD $2500.00
CMT-1 TOUCH SCREEN 15” LCD NON-SYSTEM $2751.00
DI DIGITAL INTERFACE $1600.00
CTR THERMAL RECORDER $2000.00
OO ORION OUTCOMES V2.0 $650.00
MODULES
RM8 RECEIVER MODULE $1200.00
HW8 HARDWIRE MODULE $200.00
TRANSMITTERS
TM8 DUAL CHANNEL TRANSMITTER $800.00
TM10A TELE TRENS TRANSMITTER (ECG, SP02) $2000.00
TM10 TELE TRENS TRANSMITTER (ECG, SP02, $3200.00
NIBP,RESP,TEMP)
BWI BEDSIDE TRANSMITTER $1000.00
REMOTE TERMINALS
RT HARDWIRED TOWER $4500.00
RTW WIRELESS LAPTOP $6000.00
TS TRENS STATION $14995.00
DESCRIPTIONS:
HTS820TC Central Station: The HTS820TC central station is an eight
channel central for telemetry applications.
The HTSC820TC-1 is a complete 8 channel telemetry central station
for use in any area based upon the selection of the software for
ICU,PCU or Cardiac Rehab.
The 17” monitor provided is a color monitor with mouse control only.
The transmitters and receivers are capable of providing two leads
of ECG. If desired, two of the lead wires may be removed for single
lead monitoring. The transmitter utilizes two “AAA” batteries with
approximately 200 hours operation. Each lead wire is individual
so replacement of an expensive cable is not necessary.
LASER PRINTER: Provides hard copy output of the following:
Session Report: This cover page contains all of the
patient demographic information, the exercise device information,
the rehab log and heart rate trend.
Strip Detail: Prints the ECG strips saved during the
exercise period. Five strips are printed per page. All patient
information is printed on the strip.
Full Disclosure: This is a page of every ECG complex
recorded during the exercise period.
Vital Signs Trends: Prints a trend page of blood
pressures and O2 saturation.
Uninterruptable Power Supply: Provides power to the system in
case of a power outage. It will allow the system to be safely
shut down.
Auxiliary Transmitter: Spare transmitter to be used in case one
of the 8 primary transmitters is disabled.
Mirrored Hard Drive: This is a backup hard drive that copies
all of the information from the primary drive. In case of failure
of the primary drive a switch is toggled to resume monitoring from
the mirrored drive with no loss of data.
Permanent Archive System: This is a super disk drive to store all
of the information on patients for long term archiving.
Network Interface: The network interface is used when two systems
need to communicate with each other of the hospital network. If
two systems are in the same area, only one database would have to
be maintained.
LIFE SENSING INSTRUMENTS HTS820TC
Cardiopulmonary Rehab Telemetry System
-
The number one rated system by MDBUYLINE, a nationally endorsed
capital equipment evaluation company.
-
Has rehab specific database software for cardiac and
pulmonary patients.
-
The ONLY windows based system making it easy to use, change
and repair.
-
The BEST daily session reports available. Prints automatically
on discharge.
-
Very programmable, to meet individual needs.
-
Ability to group patients for easy admitting.
-
Selectable multi-lead or single lead ECG. Arrhythmia detection.
-
Automatic Strip storage.
-
Waterproof transmitters, small lightweight 4oz, individual
patient lead wires and use AAA batteries. Means low cost
repair and replacement.
-
Pricing meets of is lower than any national contract pricing.
-
Has nationally accepted Orion Outcomes Package.
-
Includes FREE benchmarking provided by Orion.
-
Includes FREE software upgrades for life.