Click here to return to the HomePage. Click here for Sales information. Click here for Service. Click here to see our Products. Click here to see our Featured Products. Click here to order Supplies. Click here for a brief Company Profile. Click here to Contact Us.


VERSATONE Model D8

ORDER INFOMATION

Description Order Number Frequency Size Application
Versatone
Model D8
110v
220v
101-0011-030
101-0011-040
n/a see below Perioperative Doppler System
Model P81
Probe
101-0012-010 2.4 MHz 3.3 cm diameter Monitor precordial venous air 
emboli during any procedure 
where significant gravitation
gradient exists between 
heart and operating site.
Model P82
Probe
101-0013-010 8 MHz 11.5 cm pencil Assess vessel patency or 
monitor andevaluate 
blood flow at surgical site;
measure systolic blood 
pressure.
Model P83
Probe
101-0014-010 8 MHz 2.5 cm pencil Same as Model P82 Probe, 
but used when shorter
 length probe is required.
Model P84
Probe
101-0015-010 5.3 MHg 2 cm square Monitor peripheral blood
 flow. Assess vessel patency
 or monitor and evaluate 
blood flow at surgical 
site; measure systolic 
blood pressure
SPECIFICATIONS
Weight                           3.9 kg (8.5 lb.)

Dimensions                   25.4 x 25.4 x 12.2 cm (10 x 10 x 5 in.)

Power Supply                Instruments operate on internal rechargeable nickel
                                        cadmium batteries, or while charging on a line current

Power Cable                  Detachable, 3 wire grounded cord, 7 feet long, UL,
                                        CSA listed, Belden No.17250.

Line Voltage Range     105 to 130 volts (220 volt operation available)

Construction                 Rugged metal chassis, with carrying handle. Probe and
                                         accessory storage available under hinged lid.

Visual Indicators         A red panel light and repeated beeping sound when
                                         batteries are low.

Electrical Safety          All probes are electrically insulated from the operator
                                        and patient. There are no exposed crystals or delicate
                                        wires. Transformer leakage (115 volt operation) is less
                                        than 12 micro amps.


Sterilization                 Model P82 and Model P83 Probes may be sterilized
                                        with the Started sterilization system.
Note: Electrocautery Cutout is a standard accessory.
           Chart Recorder interface optional.